| Part Number: |
68-4120-001 |
| 0.03m to 1.22m (0.1 ft to 4.0 ft) |
±0.005ft/°F (±0.0027m/°C) |
| 0.03m to 1.52m (0.1 ft to 5.0 ft) |
±0.003m (±0.01 ft) |
| 0.03m to 2.13m (0.1 ft to 7.0 ft) |
±0.009m (±0.03 ft) |
| 0.03m to 3.05m (0.1 ft to 10 ft) |
±0.03m (±0.10 ft) |
| 1.22m to 3.05m (4.0 ft to 10 ft) |
±0.007ft/°F (±0.0038m/°C) |
| Baud Rate |
300, 1200, 2400, 4800 or 9600 |
| Cable |
Standard range probe - 7.6m × 0.8cm (25 ft × 0.3") Extended range probe - 15.2m × 0.8cm (50 ft × 0.3") |
| Compensated Temperature |
0° to 38°C (32° to 100°F) |
| Data Partitions |
Maximum of 6 |
| Data Points |
50 level-flow rate points. |
| Data Types |
Level, flow rate, rainfall or sample data |
| Dimensions |
24.1cm × 2.2cm (9.5" × 0.875") |
| Enclosure |
NEMA 4X, 6 (IP67) |
| Equations |
Two-term polynomial of the form K^1H^N1 ±K^2H^N2 |
| Flumes |
Parshall, Palmer-Bowlus, Leopold-Lagco, trapezoidal, H |
| Hazardous location rating |
UL Classified for Class I, Division 1, Groups A, B, C, & D locations, when installed with Isco Intrinsically Safe Barrier and Quick Disconnect Box per control drawing 60-3403-131 |
| Level Measurement Method |
Submerged pressure transducer mounted in the flow stream |
| Level Measurement Range |
0.03 to 3.05m (0.1 to 10 ft) |
| Manning Formula |
Round, U-channel, rectangular, trapezoidal |
| Material |
Body and battery end are structural foam molded polystyrene. Connector end is Ryton® (polyphenylene sulfide). |
| Materials |
Probe is Type 316 stainless steel and chlorinated polyvinyl chloride (CPVC); cable is Polyvinyl chloride (PVC) |
| Maximum Allowable Level |
6.1m (20 ft) |
| Memory Capacity |
230000 bytes; equal to over 700 days of level and rainfall readings at 15 minute intervals, plus 5000 sample events. |
| Operating Temperature |
-18°C to 60°C (0°F to 140°F) |
| Operating Temperature |
0°C to 71°C (32°F to 160°F) |
| Power |
Two 6 volt lantern batteries (alkaline recommended) or one rechargeable 12 volt Isco 947 Lead Acid Battery |
| Program Memory |
Non-volatile, programmable flash; can be updated via Interrogator port without opening enclosure |
| Sampler Activation Conditions |
Enabled, disabled, level, flow rate, rainfall and time; AND and OR combinations of any two of level, flow rate, rainfall and time; values may be above or below a set-point, inside or outside a range, or a rate of change |
| Sampler Pacing Output |
12 volt pulse |
| Serial |
Connection to IBM PC ® or compatible computer with Isco Flowlink Software |
| Size |
26.7cm × 22.9cm × 15.2cm (10.5" × 9.0" × 6.0") |
| Storage Interval |
1, 2, 5, 10, 15, 30, 60 or 120 minutes |
| Storage Modes |
Rollover, slate or triggered slate |
| Storage Temperature |
-40°C to 60°C (-40°F to 140°F) |
| Time Base Accuracy |
±1 second per day |
| Transducer Type |
Differential linear integrated circuit pressure transducer |
| Typical Battery Life (1 hour data storage interval) |
With alkaline lantern batteries - 2 years With Isco 947 Lead Acid Battery - 8 months (between recharges) Battery life is proportionately less with more frequent data storage, eg, 6 months for 15 minute storage inteval with alkaline batteries. |
| Weight (without batteries) |
3.6kg (8.0 lbs) |
| Weirs |