Chat to our customer service

Enquire Now

Complete your details below and we will be in touch as soon as possible.

*
*
*
*

Brand Info

View Gilson website

FC 203B Fraction Collector

Part Number: 171011Product Details

The FC 203B is the perfect compact fraction collector, capable of handling a wide variety of collection vessels, including microplates, vials and tubes. The built-in keypad makes setup and operation simple and efficient. Collect fractions by time, drop or peak to suit all your LC applications.


  • In peak mode, collector monitors a detector signal and identifies peaks using either an adaptive-slope algorithm or a specified millivolt threshold
  • Up to 10 programmable time windows can be added for collecting only what you want, while discarding the column’s void volume, peaks of no interest and equilibration volumes
  • Stand-alone instrument with an easy-to-use keypad, or can be controlled through your PC via TRILUTION™ Software
  • Optional 3-way diverter valve prevents contamination of collected fractions
  • Contact closure inputs are available to remotely start/advance or stop - compatible with most HPLC systems
  • Compact size fits in most fume hoods
  • Multicolumn adapters for collecting up to 18 separate channels

Gilson Product Guide

FC 203B/FC 204 Fraction Collectors Spec Sheet

FC 203B Fraction Collector Quick Reference Guide

FC 203B Fraction Collectors User's Guide

Factors and Parameters that Directly Affect Recovery of Collected Fractions in Preparative HPLC

Specifications

Part Number: 171011
3-way Valves 3-port, PTFE, 67 µL internal volume, 3.5 µL dead volume from common port to the normally closed port, up to 20 mL/min with standard or large bore needle
Communication Interface RS-232 or GSIOC; Inputs for start/advance and end/home; event mark output; one programmable output for control of peripheral devices
Data Acquisition An input channel for analog-to-digital conversion; digital data is transmitted on the GSIOC
Detector Input ±100 mV full scale
Dimensions (W × D × H) 32.4cm × 29.2cm × 26.7cm
Drop Counting Up to 9999 drops per fraction; maximum rate - 20 drops /sec
Environmental Conditions Indoor use. Altitude - up to 2000m; Temperature range - 5-40°C; Air pressure - 75-105 kPa; Pollution degree - 1 or 2, in accordance with IEC 66; Humidity - Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C
Event Marker 100 ms pulse
Front Panel Two-line, 24-character display on backlit LCD. Five command, HELP, YES, NO and 0-9 numeric hard keys; four soft keys
Manufacturing Standards Meets applicable safety and EMC certification standards; UL and CE certified
Maximum Collection Volume/Tube 20ml (28 × 60mm scintillation vials with optional Code 24 rack)
Maximum Fractions 128 (12 × 75mm tubes with optional Code 14 rack)
Multiple-Column Collection Simultaneous collection from up to 8 columns with installation of optional multiple column adaptor(s)
Multiple-Cycle Operation Repetitive collection of each sample into same set of tubes or collection of each sample into different set of tubes; 3-port, PTFE, 114ml internal volume, 6µl dead volume from the common port to the normally closed port, up to 200 ml/min with large bore needle
Number of Racks Holds one rack
Operating Modes Drop, Manual, Peak + Drop, Peak + Time, Time
Peak Detection Adaptive-slope algorithm that applies user-specified parameters to accommodate drifting baselines, negative and asymmetrical peaks, or absolute threshold level that collects all peaks above specified mV value. Peak parameters - peak height or level, in mV and peak width at half-height, in minutes. Minimum peak height for fractionation - 0.1 mV full scale. Detector-collector delay - 0.01 minute increments
Power Requirements Frequency - 50-60 Hz; Voltage - 100-120 or 220-240V, mains voltage fluctuations not to exceed ±10% of the nominal voltage; Current rating - 0.5A for 100-120V, or 0.25A for 220-240V
Programmable Time Units From 0.01 to 99.99 minutes per tube with a 0.01 minute limit of resolution
Software Via TRILUTION® LC Software
Time-Based Programming Up to 10 collection windows and 10 drain steps in any mode
Tube Change Time 100-250 ms, center to center, depending on rack type
Weight 5kg (11 lbs)
Zero Power Memory Maintains memory for a minimum of five years from date of shipment

Related Items

  • Rack, Code 0 (Eppendorf), for 80 1.5ml Eppendorf vials
  • Rack, Code 1, for 80 6/9ml 13mm diameter, 65/100mm height tubes
  • Rack, Code 2, for 119 1ml 6mm diameter, 50mm height tubes
  • Rack, Code 4, for 80 5/8ml 12mm diameter, 75/100mm height tubes
  • Rack, Code 28, for 108 3.5/4ml 10mm diameter, 65/75mm height tubes
  • Rack, Code 21, for 60 9ml 13mm diameter, 100mm height tubes
  • Rack, Code 22, for 44 25/32ml 18mm diameter, 100/150mm height tubes
  • Rack, Code 20, for 108 4.5ml 10mm diameter, 100mm height tubes
  • Rack, Code 23, for 44 6.8/8.0ml 17mm diameter, 55/65mm height scintillation vials
  • Rack, Code 24, for 14 20ml 28mm diameter, 57/60mm height scintillation vials
  • Rack, Code 29, for 60 5/6ml, 12/13mm diameter, 75mm height vials
  • Universal Rack, Code 22U, for 44 10-18mm diameter, 100-180mm height tubes
  • Rack, Code 11, for 105 9ml 13mm diameter, 100mm height tubes
  • Rack, Code 14, for 128 5/8ml 12mm diameter, 75/100mm height tubes
  • Rack, Code 15, for 1 96-well microplate (shallow)
  • FC 203B Fraction Collector, with 3-way valve
  • Rack, Code 0, for 80 2ml 12mm diameter, 32mm height vials
  • Rack, Code 23W, for 44 4ml 15mm diameter, 45mm height Wisp-style vials
  • Rack, Code 29SE, for 60 0.5ml Eppendorf vials
  • Rack, Code 29LE, for 60 1.5ml Eppendorf vials
  • Rack, Code 30, for 60 2ml 12mm diameter, 32mm height vials
  • Rack, Code 32, for 60 6ml 13mm diameter, 65mm height tubes
  • Rack, Code 33, for 14 20ml 28mm diameter, 57mm height scintillation vials
  • Rack, Code 30P, polypropylene, for 60 2ml 12mm diameter, 32mm height vials
  • Rack, Code 33P, polypropylene, for 14 20ml 28mm diameter, 57mm height scintillation vials