Chat to our customer service

Enquire Now

Complete your details below and we will be in touch as soon as possible.

*
*
*
*

Brand Info

View Martin Christ website

Alpha 2-4 LDplus Freeze Dryer, watercooled

Part Number: 101553Product Details

Overview

Universal laboratory freeze dryer for routine applications; low ice condenser temperature allow drying of samples containing organic solvents (eg, alcohols); with new user friendly unit control "LYO Display LDplus".

LDplus (Lyo Display Plus) stands for a comfortable, easy-to-use and self-explaining user interface for controlling routine freeze drying processes, combining functionality and convenient operation.

Based on over 50 years of experience, Martin Christ presents a comprehensive product range covering routine applications as well as reliable equipment for individual and product specific drying processes. The newly introduced freeze dryers with LDplus- and LSC-controller set new standards for flexibility and process control. The modular accessory line allows for individual system configurations adaptable to almost every freeze-drying application. Two different drying techniques provide a solution to most lyophilisation challenges.
Features

• Graphic LC display with a clear layout showing the most important process data (ice condenser temperature, process time, section time and vacuum)
• Comfortable and self-explaining menu guidance in German, English or French language
• Vacuum control for optimisation/reduction of process times (electromagnetic pressure control valve available as accessory)
• Conversion of product temperature and vacuum according to the vapour pressure curve above ice
• RS-232 communications interface (PC) available as an option, eg, for process documentation software LyoLog LL-1

Benefits

Watercooled, cascaded refrigerators 2×0.51 kW, CFC and H CFC-free refrigerant, without vacuum pump, bench top unit, integrated support plate for direct mounting of acrylic chambers or accessories with a diameter of 300 mm, stainless steel worktop, ice condenser and ice condenser chamber with drain valve for defrosted water, ice capacity maximum 4kg, ice condenser performance maximum 4kg/24h, ice condenser temperature approximately -85°C, ice condenser chamber 6.5 litres, vertical lay-out, suitable for freeze drying in round flasks, wide neck closed filter bottles and/or on unheated shelves, also suitable as a cooling trap for rotational-vacuum-concentrators, equipped with process controller LDplus (Lyo-Display-plus): Clearly arranged graphic LC-display showing the process data (ice condenser temperature, process time, section time and vacuum in combination with vacuum measuring sensor A VSP 62 MV, part number 125478), easily operated and intuitional menu navigation in German, English and French language, conversion of temperature and vacuum according to the vapour pressure above ice, vacuum control possible in connection with pressure control valve part number 125910, standard voltage 230V, 50 Hz.

Applications

Suitable for drying in 12 or 24 round bottom flasks, wide neck filter bottles, ampoules and on 3 or 5 unheated shelves of 265mm diameter or 5 unheated shelves of 360mm diameter, alternatively sealing device with 2 or 4 unheated shelves of 250mm diameter).

Specifications

Part Number: 101553
Dimensions of Base Unit (W × H × D) 390mm × 415mm × 555mm
Drying in Round Bottom Flasks Maximum 24 pieces
Electrical Connection (other voltages available) 230V, 50-60 Hz
Ice Condenser Capacity Maximum 4kg
Ice Condenser Performance Maximum 4kg/24h
Ice Condenser Temperature Approximately -55°C
Maximum Ambient Temperature (unit is air-cooled, higher temperatures upon request) Climate category SN
+10°C to +32°C
Maximum Current Approximately 4.5 A
Maximum Power Consumption Approximately 1.00 kVA
Maximum Shelf Surface Area, when drying outside the ice condenser chamber 5 shelves
360mm diameter
<= 0.5m²
Shelf Temperature, when pre-freezing inside the ice condenser chamber Approximately -25°C
Weight Approximately 42kg

Related Items

  • Epsilon 2-4 Freeze Dryer, 230V, 50 Hz
  • Beta 2-8 LDplus Freeze Dryer, aircooled
  • Alpha 2-4 LDplus Freeze Dryer, aircooled
  • Alpha 1-4 LDplus Freeze Dryer, aircooled
  • Delta 2-24 LSC TCS Freeze Dryer, watercooled
  • Beta 2-8 LDplus Freeze Dryer, watercooled and with defrost heating at bottom and casing at ice condenser chamber
  • Delta 1-24 LSC Freeze Dryer, aircooled
  • Delta 2-24 LSC Freeze Dryer, aircooled
  • Alpha 2-4 LDplus Freeze Dryer, watercooled and with defrost heating at bottom and casing at ice condenser chamber
  • Epsilon 1-4 Freeze Dryer, 230V, 50 Hz
  • Beta 1-8 LDplus Freeze Dryer, aircooled
  • Gamma 1-16 LSC Freeze Dryer
  • Alpha 1-2 LDplus Freeze Dryer
  • Alpha 1-4 LDplus Freeze Dryer, watercooled and with defrost heating at bottom and casing at ice condenser chamber
  • Alpha 1-4 LDplus Freeze Dryer, watercooled
  • Alpha 2-4 LDplus Freeze Dryer, additional with defrost heating at bottom and casing at ice condenser chamber
  • Gamma 2-16 LSC Freeze Dryer
  • Alpha 1-2 LDplus Freeze Dryer package
  • Delta 1-24 LSC TCS Freeze Dryer, watercooled
  • Epsilon 1-6D Freeze Dryer, 3 × 400V, 50 Hz
  • Epsilon 2-6D Freeze Dryer, 3 × 400V, 50 Hz
  • Beta 1-8 LDplus Freeze Dryer, watercooled and with defrost heating at bottom and casing at ice condenser chamber
  • Alpha 1-4 LDplus Freeze Dryer, with defrost heating at bottom and casing at ice condenser chamber