300mm Resist-Torr® Photoresist Detection Monitor

Part Number: 300mm Resist-TorrProduct Details

Overview

It is often difficult to know when a photoresist problem is affecting the productivity of a 300mm PVD system. Even small amounts of residual resist, when introduced over a prolonged period, can reduce yields, cause particle contamination or slowly contaminate process chambers, thereby requiring premature kit changes. Major photoresist hits can be very costly, upwards of hundreds of thousands of dollars for lost wafers, especialy if the tantalum/copper target becomes contaminated.

Resist can be inadvertently introduced to PVD systems in a number of ways. Rushing Hot Lots through opens the door to skipping steps like the resist strip or even the complete etch and strip cycle. This could result in contamination throughout the process tool if the wafer is not stopped at the degas chamber. Such process flow errors can impact PVD tool performance, immediately, from a single wafer. More common, however, is the incomplete removal of resist. This can happen due to a poorly controlled end point in the asher such as from first-wafer, cold-chamber effects, or from faults on integrated etch/strip tools.

Each of these mechanisms can leave resist contamination on wafers which eventually is seen as a loss of die or high particle densities in sputter etch process chambers. Resist contamination can be the cause of a series of factors, all of Installation Schematic which work to reduce tool availability, increase COO, and decrease the overall yield of a process flow.
Features

The 300mm Resist-Torr®
The 300mm Resist-Torr consist of an optimum combination of a closed ion source quadrupole mass analyser with fast response capilary inlet, together with advanced proprietary algorithms developed exclusively for the degas chambers on industry leading 300mm PVD cluster tools. When utilised with the powerful features of Process Eye™ sensor control software package, the result is completely automated operation and highly reliable photoresist detection. Unscheduled downtimes are reduced and device yields are improved.

The 300mm Resist-Torr considers many different parameters of the degas step and combines that data provide information in the form of a meaningful number, without the need for user-interpretation. This measurement, termed the PR Index®, is a normalised measure of wafer borne photoresist contamination that can be presented in various forms to compare data over time. The 300mm Resist-Tor can interrupt the processing of any wafer automatically, without operator intervention, if a wafer enters the vacuum system with detrimental levels of residual photoresist, as determined by the PR Index.


Click the picture for a closer look

Benefits

• Fully automated process monitoring – no operator necessary
• Detection of photoresist contamination during high pressure (~8 Torr) degas, before wafers enter into 300mm PVD chambers
• Calculation of the PR Index® - a measure of photoresist contamination level in the degas chamber
- WARN and STOP levels for photoresist contamination
- Can stop the progress of a contaminated wafer through the tool
- Sensitive enough to detect even smal amounts of resist commonly found on product wafers
- Increase die yield asociated with reduced particle contamination
• Built in calibration standard with automatic calibration routine enables long-term data comparison and proper system operation
• Variable alarm sensitivity to match the conditions of your product in your fab or process tool
• Powerful optional data review feature to maximise ROI
- Faster PM recovery through vacuum analysis helps minimise chamber turnaround time
- Highlights chronic, low-level residual photoresist contamination that can cause reduced PreClean kit-life and excess particles
- Reports of gases and PR Index for comparisons, as well as for long term trend analysis

Specifications

Part Number: 300mm Resist-Torr
Bakeout Temperature & Bakeout Jacket Included for 20°C bakeout
Calibration Hardware Reference gas standard for automated calibration
Communications (baud rate & max. distance) RS232C [9600 baud, 15m (50ft.)]
RS422 [115000 baud, 1.2km (4000 ft)]
Detector System Dual (Faraday and Secondary Electron Multiplier)
Filaments Replaceable twin Thoria filaments
Analyser Housing Base Pressure: Better than 0.000000005 Torr after bake out
Foreline Pump Dry diaphragm standard
I/O Capability Tool alarm relay
Inlet Dual path with fast-response capillary for degas monitoring and high conductance for base vacuum. Includes heater jacket.
Ion Source High sensitivity, closed ion source
LED Status Indication Filament 1, filament 2, SEM, power and communications
Mass Filter Double filter (1" "RFonly" pre-filter with 4" main filter)
Mass Range 1-200 amu
Mass Stability Better than ±0.1 amu over 8 hours at stable ambient temperature
Maximum Ambient Operating Temperature 35°C, 80% RH (non-condensing)
Minimum Detectable Concentration <10pb for all common gases except <10ppm for H2
Minimum PC Specification Required Intel® Pentium III® 450-800 MHz, 64-256 MB RAM, 6-12 GB hard drive, dependent upon total number of sensors on the computer
Mounting Flange 2.75" Conflat® flange, SS capillary
Other Features Leakcheck headset socket with audio adjustment, external filament trip socket, instrument reset
Pneumatics 60-80 psig CDA
Power Single-phase AC, 50/60 Hz, 100-120 V or 220-240V, 500 Watts
Resolution Better than 10% valley between peaks of equal height throughout them as
range
RGA Controler to Vacuum System Cables 9m (30 ft) standard, other lengths available
Shipping Weight Approx. 38.5kg (85 lbs); can vary depending upon configuration
Software Process Eye™ fully network compatible control platform operating under Microsoft® Windows® 98, NT® 4.0, Me, 2000*, or XP* (* recommended)
Vacuum Hardware 60 l/s turbomolecular pump with high conductance analyser housing, fast response capillary inlet system, automated vacuum controller (RVC), completely interlocked and integrated
Weight at Tool Approx. 11kg (24 lbs) to bolton process system (support stand or bracket
required)

Related Items

  • CIRAS-DC Differential CO2/H2O IRGA, for PC operation
  • CIRAS-SC Absolute CO2/H2O IRGA, for PC operation
  • SBA-5 CO2 Gas Analyser (High Range)
  • SBA-5 CO2 Gas Analyser, with enclosure
  • SBA-5 CO2 Gas Analyser (High Range), with enclosure
  • WMA-4 Single Channel CO2 Analyser
  • WMA-4 Single Channel CO2 Analyser (High Range)
  • WMA-4 Dual Channel CO2 Analyser
  • WMA-4 Dual Channel CO2 Analyser (High Range)
  • EGM-4 Environmental Gas Monitor for CO2
  • EGM-4 Environmental Gas Monitor for CO2 -12V NiMH
  • EGM-4 Environmental Gas Monitor for CO2 (High Range)
  • EGM-4 Environmental Gas Monitor for CO2 -12V NiMH (High Range)
  • MultiGas™ Purity Real-Time Trace Impurity Detection
  • MultiGas™ 2030 Continuous Gas Analysis
  • MultiGas™ 2030 HS 5Hz Combustion Analysis
  • Process Sense™ Chamber Clean Endpoint Detector
  • MicroVision Plus Smart Head RGA
  • e-Vision™/e-Vision+™ Web-enabled RGA for Vacuum Monitoring and e-Diagnostics
  • 200mm Resist-Torr® Photoresist Detection Monitor
  • HPQ2 High Pressure Residual Gas Analyser
  • HPQ2S High Pressure Residual Gas Analyser, with special gas-specific algorithms to compensate for sensitivity variations
  • Cirrus™ Quadrupole Mass Spectrometry