2150 Area Velocity Flow Module, with 2191 Battery Module

Part Number: 682050002Product Details

Overview

Continuous wave Doppler flow meter is ideal for portable flow surveys and permanent installations
The 2150 Flow Module uses continuous wave Doppler technology to measure mean velocity. The sensor transmits a continuous ultrasonic wave, then measures the frequency shift of returned echoes reflected by air bubbles or particles in the flow.

The 2150's "smart" area velocity probe is built on digital electronics, so the analog level is digitised in the sensor itself to overcome electromagnetic interference. The probe is also factory-calibrated for 3 metre (10 foot) span at different temperatures. This built-in calibration eliminates drift in the level signal, providing long-term level stability that reduces recalibration frequency and completely eliminates span recalibration.

In field use, the 2150 is typically powered either by two alkaline, or Isco Rechargeable Lead-acid batteries, within a 2191 Battery Module. Highly efficient power management extends battery life up to 15 months at 15-minute data storage intervals. Other power options (including solar) are available.
Features

• Rugged, submersible enclosure meets NEMA 4X, 6P (IP68) environmental specs.
• Chemically resistant epoxy-encapsulated sensor withstands abuse, resists oil and grease fouling, and eliminates the need for frequent cleaning.
• Replaceable high-capacity internal desiccant cartridge and hydrophobic filter protect sensor reference from water entry and internal moisture.
• Pressure transducer vent system automatically compensates for atmospheric pressure changes to maintain accuracy.
• The quick-connect sensor can be easily removed and interchanged in the field without requiring recalibration.
• Up to four 2100 Series flow modules can be networked by stacking and/or extension cables.
• Secure data storage. All data are continuously stored in flash memory to protect against loss in case of power failure
• Easy to upgrade. New operating software can be downloaded into non-volatile flash memory, without affecting stored program and data.
• Records and stores input voltage and temperature data.
• Variable rate data storage lets you change the data storage interval when programmed conditions occur. This feature assures maximum information about an exceptional event - such as an overflow - while conserving power and data capacity during normal conditions.
• 38400 bps communication provides speedy setup and data retrieval.

Applications

• Stack modules you need to build a compact, integrated system
• Monitor multiple flow streams at the same time
• Obtain redundant measurements to guarantee integrity
• Remotely locate modules and connect them via cable
• Expand your monitoring system as your requirements evolve

Specifications

Part Number: 682050002
Accuracy ±0.003m from 0.01m to 3.05m (±0.01 ft from 0.033 ft to 10 ft)
Accuracy ±2°C (±3.6°F)
Batteries Two 6-volt Energiser Model 529* alkaline (25 Ahrs capacity) or Isco Rechargeable Lead-acid (5 Ahrs capacity) recommended
* Note - Energiser 529 ER does not give specified life
Cable (Length × Diameter) 7.6m × 9mm (25 ft × 0.37") standard. Custom lengths available on request.
Compensated Range 0°C to 50°C (32°F to 122°F)
Data Retrieval Serial connection to PC or optional 2101 Field Wizard module; optional modules for spread spectrum radio; land-line or cellular modem; 1xRTT. Modbus and 4-20 mA analog available
Data Storage Non-volatile flash; retains stored data during program updates. Capacity 395000 bytes (up to 79000 readings, equal to over 270 days of level and velocity readings at 15 minute intervals, plus total flow and input voltage readings at 24 hour intervals)
Data Types Level, velocity, flow rate 1, flow rate 2, total flow 1, total flow 2, input voltage, temperature
Enclosure NEMA 4X, 6P (IP68)
Enclosure (self certified) NEMA 4X, 6P, (IP68)
Flow Rate Conversions Up to 2 independent level-to-area conversions and/or level-to-flow rate conversions
Level-to-Area Conversions Channel Shapes - round, U-shaped, rectangular, trapezoidal, elliptical, with silt correction
Data Points - Up to 50 level-area points
Level-to-Flow Conversions Most common weirs and flumes; Manning Formula; Data Points (up to 50 level-flow points); 2-term polynomial equation
Long-Term Stability ±0.007 m/yr (±0.023 ft/yr)
Material High-impact polystyrene, stainless steel
Materials of Construction Sensor - Epoxy, chlorinated polyvinyl chloride (CPVC), stainless steel
Cable - Polyvinyl chloride (PVC), chlorinated polyvinyl chloride (CPVC)
Materials of Construction High-impact polystyrene, stainless steel
Maximum Allowable Level 10.5m (34 ft)
Method Doppler ultrasonic, frequency 500 kHz
Method Submerged pressure transducer mounted in the flow stream
Multi-Module Networking Up to four 2100 Series Flow Modules, stacked and/or remotely connected. Maximum distance between modules 1000m (3300 ft).
Operating Temperature 0°C to 60°C (32°F to 140°F)
Power Required 12 VDC nominal (7.0 to 16.6 VDC), 100 mA typical, 1 mA standby
Power Source Typically, an Isco 2191 Battery Module, containing 2 alkaline or 2 rechargeable lead-acid batteries. (Other power options are available; ask for details.)
Program Memory Non-volatile programmable flash; can be updated using PC without opening enclosure; retains user program after updating
Range -1.5 to +6.1 m/s (-5 to +20 ft/s)
Range Standard - 0.010m to 3.05m (0.033 ft to 10 ft)
Optional - up to 9.15m (30 ft)
Serial Communication Speed 38400 bps
Size (H × W × D) 19mm × 33mm × 152mm (0.75" × 1.3" × 6.0")
Size (H × W × D) 7.4cm × 28.7cm × 19.1cm (2.9" × 11.3" × 7.5")
Size (H × W × D) 152mm × 244mm × 193mm (6.0" × 9.6" × 7.6")
Software Isco Flowlink for setup, data retrieval, editing, analysis, and reporting
Storage Interval 15 or 30 seconds; 1, 2, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours; Storage rate variable based on level, velocity, flow rate, total flow, or input voltage
Storage Mode Rollover; 5 bytes per reading
Temperature Range -40°C to 60°C (-40°F to 140°F) operating and storage
Total Flow Calculations Up to 2 independent, net, positive or negative, based on either flow rate conversion
Transducer Type Differential linear integrated circuit pressure transducer
Typical Battery Life (using 15-minute data storage interval) Energiser® Model 529 alkaline - 15 months
Isco rechargeable lead-acid - 2.5 months
Typical Minimum Depth 25mm (0.08 ft)
Weight 0.9kg (2.0 lbs)
Weight (including cable) 1kg (2.2 lbs)
Weight (without batteries) 1.4kg (3.2 lbs)

Related Items

  • 2110 Ultrasonic Flow Module, with 1.5 meter level sensor, 2191 battery module and in-pipe mount
  • 2110 Ultrasonic Flow Module, with 1.5 meter level sensor
  • Portable 2160 LaserFlow™ System
  • This system includes TIENet™ 360 LaserFlow Sensor with 10m (32.8 foot) cable, 2160 LaserFlow module, 2191 Battery module with carrying handle and suspension strap. The system includes one 2100 Series maintenance kit, instruction manual, and coupon for free Isco Open Channel Flow Measurement Handbook. Requires wall mount or temporary mount for LaserFlow sensor, Flowlink software and computer connect cable.
  • Portable 2160 LaserFlow™ System with Surcharge Kit
  • This system includes TIENet™ 360 LaserFlow Sensor with 10m (32.8 foot) cable, TIENet 350 Area Velocity Sensor Surcharge Kit, 2160 LaserFlow module, 2191 Battery module with carrying handle and suspension strap. The system includes one 2100 Series maintenance kit, instruction manual, and coupon for free Isco Open Channel Flow Measurement Handbook. Requires wall mount or temporary mount for LaserFlow sensor, Flowlink software and computer connect cable.
  • Permanent 2160 LaserFlow™ System
  • This system includes TIENet™ 360 LaserFlow Sensor with 10m (32.8 foot) cable, and 2160 LaserFlow module. The system includes one 2100 Series maintenance kit, instruction manual, and coupon for free Isco Open Channel Flow Measurement Handbook. Requires Flowlink software and computer connect cable. Requires an external 12 VDC power source, wall mount or temporary mount for LaserFlow sensor, mount for 2160 module, Flowlink software and computer connect cable.
  • Permanent 2160 LaserFlow™ System with Surcharge Kit
  • This system includes TIENet™ 360 LaserFlow Sensor with 10m (32.8 foot) cable, TIENet 350 Area Velocity Sensor Surcharge Kit, and 2160 LaserFlow module. The system includes one 2100 Series maintenance kit, instruction manual, and coupon for free Isco Open Channel Flow Measurement Handbook. Requires an external 12 VDC power source, wall mount or temporary mount for LaserFlow sensor, mount for 2160 module, Flowlink software and computer connect cable.
  • 2160 LaserFlow™ module with 2191 Battery Module
  • DOES NOT INCLUDE TIENet 360 LaserFlow Sensor. Includes carrying handle and suspension strap, instruction manual, maintenance kit, and coupon for free Isco Open Channel Flow Measurement Handbook.
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 5m (16.4 ft) cable
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 5m (16.4 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature Bubbler Flow Meter with internal bubbler level sensor assembly with 3.05m (10 ft) measurement range
  • Signature® LaserFlow System with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable
  • Signature® LaserFlow System with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® LaserFlow system with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable
  • Signature® LaserFlow system with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® LaserFlow system with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 5m (16 ft) cable
  • Signature® LaserFlow system with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 5m (16 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature Base Station
  • Signature Base Station
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 5m (16 ft) cable
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 5m (16 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • 3010 Ultrasonic Flow Transmitter
  • 2110 Ultrasonic Flow Module, with 1.5 meter level sensor and 2191 battery module
  • 2110 Ultrasonic Flow Module, with 1.5 meter sensor and in-pipe mount
  • 10 inch Metering Insert with Pump and Poles
  • 12 inch Metering Insert with Pump and Poles
  • 2150 Area Velocity Flow Module, includes Area Velocity Sensor with 3m (10 ft) level measurement range and 10m (33 ft) cable