Chat to our customer service

Enquire Now

Complete your details below and we will be in touch as soon as possible.

*
*
*
*

Brand Info

View ISCO (Teledyne) website

4220 Submerged Probe Flow Meter, with submerged probe with 10 foot cable

Part Number: 68-4220-001Product Details

Overview

Submerged probe accuracy unaffected by wind, steam, foam, turbulence or air temperature change.
The probe on the Isco 4220 uses a differential pressure transducer to measure the depth of the liquid. The probe accurately senses pressure even when covered with silt and sand, and the venting system automatically compensates for changes in atmospheric pressure. This technology provides accurate measurement at sites where wind, steam, foam, turbulence, or air temperature fluctuations exist.

Isco mounting rings make it easy to install the probe in round pipes and manhole inverts. With the Isco Street Level Installation Tool, you can install your monitoring system from ground level, eliminating the costs and hazards of entering manholes. Most flumes are available with an integral recess for mounting an Isco Submerged Probe.
Features

• Built-in level-to-flow conversions for most applications
• Choice of standard (10 foot) and extended (30 foot) level measurement range
• Venting system automatically compensates for atmospheric pressure changes
• Two-line × 80-character backlit LCD
• Built-in dot matrix printer gives you an accurate, on-site printout
• Internal memory stores over 2 months of data
• Easy interfacing for Sampler, water quality sonde, alarm outputs

Applications

• Flow measurement in Class 1 Div 1 locations (Flowmeter in safe area)
• Pretreatment Compliance
• Stormwater Runoff Monitoring
• Permit Enforcement
• Sewer Flow Monitoring
• Combined Sewer Overflow Studies
• Wastewater Treatment Plant Operations
• Inflow and Infiltration Studies
• River and Stream Gauging

Specifications

Part Number: 68-4220-001
0.03m to 1.22m (0.1 ft to 4.0 ft) ±0.0027m/°C (±0.005ft/°F)
0.03m to 1.52m (0.1 ft to 5.0 ft) ±0.003m (±0.01 ft)
0.03m to 2.13m (0.1 ft to 7.0 ft) ±0.009m (±0.03 ft)
0.03m to 3.05m (0.1 ft to 10 ft) ±0.03m (±0.10 ft)
1.22m to 3.05m (4.0 ft to 10 ft) ±0.0038m/°C (±0.007ft/°F)
934 NiCad Battery 8 to 11 days
946 Lead-Acid Battery 12 to 16 days
948 Lead-Acid Battery 2.5 to 3 months
Cable Polyvinyl chloride (PVC)
Cable, standard range probe 7.6m × 0.8cm (25 ft × 0.3")
Compensated Temperature 0°C to 38°C (32°F to 100°F)
Dimensions 24.1cm × 2.2cm (9.5" × 0.875")
Display Backlit LCD, 2-line, 80-character (5.5mm high × 3.2mm wide)
Enclosure NEMA 4X (iP65)
Level Measurement Method Submerged pressure transducer mounted in the flow stream
Level Measurement Range 0.03m to 3.05m (0.1 ft to 10 ft)
Material High-impact molded polystyrene structural foam
Maximum Allowable Level 6.1m (20 ft)
Operating Temperature 0°C to 71°C (32°F to 160°F)
Operating Temperature -18°C to 60°C (0°F to 140°F)
Power 12 to 14V DC, 24 mA average at 12.5V DC
Program Memory Non-volatile, programmable flash. Updateable without opening enclosure.
Size (H × W × D, without power source) 43cm × 29cm × 26.7cm (17.0" × 11.5" × 10.5")
Storage Temperature -40°C to 60°C (-40°F to 140°F)
Submerged Probe Type 316 stainless steel, chlorinated polyvinyl chloride (CPVC)
Transducer Type Differential linear integrated circuit pressure transducer
Weight (without power source) 7.8kg (17.3 lbs)

Related Items

  • 2110 Ultrasonic Flow Module, with 1.5 meter level sensor, 2191 battery module and in-pipe mount
  • 2110 Ultrasonic Flow Module, with 1.5 meter level sensor
  • Portable 2160 LaserFlow™ System
  • This system includes TIENet™ 360 LaserFlow Sensor with 10m (32.8 foot) cable, 2160 LaserFlow module, 2191 Battery module with carrying handle and suspension strap. The system includes one 2100 Series maintenance kit, instruction manual, and coupon for free Isco Open Channel Flow Measurement Handbook. Requires wall mount or temporary mount for LaserFlow sensor, Flowlink software and computer connect cable.
  • Portable 2160 LaserFlow™ System with Surcharge Kit
  • This system includes TIENet™ 360 LaserFlow Sensor with 10m (32.8 foot) cable, TIENet 350 Area Velocity Sensor Surcharge Kit, 2160 LaserFlow module, 2191 Battery module with carrying handle and suspension strap. The system includes one 2100 Series maintenance kit, instruction manual, and coupon for free Isco Open Channel Flow Measurement Handbook. Requires wall mount or temporary mount for LaserFlow sensor, Flowlink software and computer connect cable.
  • Permanent 2160 LaserFlow™ System
  • This system includes TIENet™ 360 LaserFlow Sensor with 10m (32.8 foot) cable, and 2160 LaserFlow module. The system includes one 2100 Series maintenance kit, instruction manual, and coupon for free Isco Open Channel Flow Measurement Handbook. Requires Flowlink software and computer connect cable. Requires an external 12 VDC power source, wall mount or temporary mount for LaserFlow sensor, mount for 2160 module, Flowlink software and computer connect cable.
  • Permanent 2160 LaserFlow™ System with Surcharge Kit
  • This system includes TIENet™ 360 LaserFlow Sensor with 10m (32.8 foot) cable, TIENet 350 Area Velocity Sensor Surcharge Kit, and 2160 LaserFlow module. The system includes one 2100 Series maintenance kit, instruction manual, and coupon for free Isco Open Channel Flow Measurement Handbook. Requires an external 12 VDC power source, wall mount or temporary mount for LaserFlow sensor, mount for 2160 module, Flowlink software and computer connect cable.
  • 2160 LaserFlow™ module with 2191 Battery Module
  • DOES NOT INCLUDE TIENet 360 LaserFlow Sensor. Includes carrying handle and suspension strap, instruction manual, maintenance kit, and coupon for free Isco Open Channel Flow Measurement Handbook.
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 5m (16.4 ft) cable
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 5m (16.4 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable
  • Signature® Ultrasonic Flow Meter with TIENet™ 310 ultrasonic sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature Bubbler Flow Meter with internal bubbler level sensor assembly with 3.05m (10 ft) measurement range
  • Signature® LaserFlow System with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable
  • Signature® LaserFlow System with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® LaserFlow system with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable
  • Signature® LaserFlow system with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® LaserFlow system with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 5m (16 ft) cable
  • Signature® LaserFlow system with TIENet™ 360 LaserFlow sensor, 3.05m (10 ft) measurement range, with 5m (16 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature Base Station
  • Signature Base Station
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 5m (16 ft) cable
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 5m (16 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 10m (32 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable
  • Signature® Area Velocity Flow Meter with TIENet™ 350 area velocity sensor, 3.05m (10 ft) measurement range, with 23m (75 ft) cable. Includes one TIENet cord grip fitting (209-0073-12) for watertight sensor cable connection to the Signature meter in non-conduit applications.
  • 3010 Ultrasonic Flow Transmitter
  • 2110 Ultrasonic Flow Module, with 1.5 meter level sensor and 2191 battery module
  • 2110 Ultrasonic Flow Module, with 1.5 meter sensor and in-pipe mount
  • 10 inch Metering Insert with Pump and Poles
  • 12 inch Metering Insert with Pump and Poles
  • 2150 Area Velocity Flow Module, includes Area Velocity Sensor with 3m (10 ft) level measurement range and 10m (33 ft) cable